Working safely with hazardous substances: reliable instrumentation as the key to PGS compliance

Knowledge article

4 August 2026
In industries that handle hazardous substances, safety is a continuous process. In the Netherlands, the Hazardous Substances Publication Series (Publicatiereeks Gevaarlijke Stoffen, or PGS) sets the framework within which companies must demonstrably control the risks of their activities involving hazardous substances. With recent updates, including the new PGS 40 guideline for hydrogen electrolysis, that framework is very much in motion.

One principle recurs throughout nearly every guideline: a safety measure is only as reliable as the instrumentation that monitors it. This article shows how reliable, traceable measurement and calibration instrumentation from Tradinco helps deliver on those safety objectives.

The PGS in brief

The PGS consists of guidelines for the storage and transfer of hazardous substances, aimed at safeguarding the surrounding area, the environment and workers. Since 2015 the guidelines have been converted to the PGS New Style: a risk-based approach in which undesired events, scenarios, objectives and measures are explicitly linked (the BowTie method). Recent updates include PGS 40 (hydrogen electrolysis), PGS 15 (storage of packaged hazardous substances), PGS 12 (ammonia) and PGS 29 (flammable liquids).

The common thread: measures require reliable measurement

Virtually every PGS guideline sets requirements for controlling pressure, temperature and leak tightness. An overpressure protection that is not correctly set, or a temperature monitor that drifts: in those cases the measure exists on paper, but safety cannot be demonstrably guaranteed. This is where calibrated instrumentation makes the difference: not as a replacement for PGS measures, but as the infrastructure that lets an organisation *demonstrate* that its installations operate safely and within specification. Tradinco performs these calibrations under ISO/IEC 17025 accreditation (RvA, certificate K050), providing the traceability that regulators expect.
Gevaarlijke stoffen

Pressure measurement and overpressure protection


PGS guidelines consistently require demonstrably functioning protection against overpressure. Pressure gauges, transmitters, switches and safety valves must be validated periodically.

The Tradinco portfolio covers this chain end to end. For traceable calibration there are automatic pressure calibrators such as the WIKA CPC6050 and CPC4000, the PACE series (PACE5000 E/6000 E), and deadweight testers like the Traqc-22 DWT as a primary standard. In the field, pressure sensors and switches from Druck (UNIK 5000, RPS/DPS 8000) , Labom and MPL provide continuous monitoring. For mobile use, portable calibrators such as the Druck DPI 610E and the Traqc-8 series offer a solution.
Would you like to know which Tradinco solutions fit your specific PGS obligations? Contact our specialists at sales@tradinco.com for tailored advice.

Leak tightness and leak testing

Preventing and detecting leaks at an early stage is a core theme in PGS 15, 29, 31 and 36, among others. Tradinco's leak testers and vacuum leak testers objectively establish the integrity of valves, piping and storage facilities based on differential pressure and flow. For situations requiring a targeted assessment, Tradinco's leak-testing service complements this. For applications with the strictest tightness requirements, measurements can extend into very low leakage rates.

Temperature monitoring

Several PGS guidelines set requirements for the temperature control of stored substances. With temperature sensors and switches from Labom, Druck, and dry-block calibrators such as the Druck PTC series (PTC165/200/700) and DryTC165/650, these parameters can be both monitored and validated periodically.

Hydrogen applications: PGS 36 and the new PGS 40

The rise of hydrogen is the clearest example of a rapidly evolving safety framework. With PGS 36 (hydrogen) and the new PGS 40 (production via electrolysis), specific requirements for pressure control and leak tightness come into focus. The Druck RPS/DPS 8000H sensors are specifically suited to accurate pressure measurements in hydrogen applications, making them an excellent fit for electrolysis installations and hydrogen storage.

Electrical safety and inspections

The PGS New Style explicitly incorporates occupational safety. For electrical installations within an environment containing hazardous substances, Tradinco offers NEN 3140 inspections and accredited electrical calibrations, supported by instrumentation such as the Druck DPI 620 Genii.

Conclusion: from measure to demonstrable assurance

The PGS prescribes which risks must be controlled and with which measures. The step to demonstrable safety in practice depends entirely on reliable measurement. That is where the added value of Tradinco's instrumentation, calibration and services lies: the infrastructure that enables companies to demonstrate that their installations operate safely and within specification: today, and at every future revision of the framework.

Related news

Knowledge article

The hidden moisture source in your optical system — and why dew point measurement is the key

When purging optical systems with nitrogen, the air inside the housing is often assumed to be the main culprit. But the real source of moisture is usually found elsewhere — and that has significant implications for how a purging process should be set up and verified.
view
News

UPS4E-IS from Druck is now available

The long-awaited UPS4E-IS from Druck is now available. Specifically designed for hazardous (explosive) environments, the instrument enables work to be carried out directly within ATEX zones.
view
Knowledge article

Precision in measurement and calibration technology for defence & security

In the defence and security sector, certainty is essential. Equipment must be correct, measurements reliable, and calibrations must meet the standards.
view