Knowledge article
20 April 2026
The misconception: the air is not the problem
A common assumption is that the moisture in a sealed optical system is primarily contained in the air trapped during assembly or maintenance. In practice, this turns out to be a misconception. The majority of moisture resides in the hygroscopic materials inside the system: printed circuit boards (PCBs), plastic housings, cable feedthroughs, and seals actively absorb moisture from their surroundings and gradually release it — even after the housing has been closed, and even when the system is already under positive pressure.This has a practical consequence: a purge cycle that only removes the air is insufficient. An effective purging process requires multiple pressure-cycling steps to extract moisture from these hygroscopic materials as well. The only way to be certain this has been achieved is by measuring the dew point of the outflowing gas — not by applying a fixed purge duration.

Dew point as the only reliable benchmark
Traditional purging methods — where nitrogen flows through the system via one inlet port and is measured at the outlet — have a fundamental drawback: the gas takes the path of least resistance. In cavities, crevices, and spaces behind components, moist air can remain trapped while the flowing gas already shows a low reading.
A single-point purge system works differently: the system is pressurised with dry nitrogen, after which the gas flows back across a dew point sensor. This approach measures not only the air, but also the moisture released from components during the pressure cycle. Only when the dew point of the outflowing gas has reached the target value is the purge process demonstrably complete.
“When purging optical systems with nitrogen, the air inside the housing is often assumed to be the main culprit. But the real source of moisture is usually found elsewhere — and that has significant implications for how a purging process should be set up and verified.”
Optical coatings: particularly vulnerable to moisture
Beyond surface condensation on lenses, there is a less well-known but equally damaging form of moisture-related harm: degradation of anti-reflective and other optical coatings. Even minimal moisture exposure can alter the layer thickness and refractive index of these coatings, directly affecting light transmission, resolution, and system accuracy. For high-power lasers this is especially critical: altered coatings can significantly reduce output energy or distort the beam.Nitrogen with a dew point of -70°C or lower — as required for high-end optronic systems — ensures that no free water is present to attack these coatings. Standard bottled nitrogen typically already has a moisture content below 10 ppm (equivalent to a dew point of -60°C), but quality can deteriorate during transport and filling. Measuring the dew point of the incoming gas is therefore just as important as measuring the outgoing gas.
Leak testing: the second half of the equation
A successful nitrogen purge is only half of the maintenance process. A system that is not hermetically sealed after purging will reabsorb moisture at the very first temperature change, through micro-leaks in seals or connections. Leak testing is therefore not optional — it is an integral part of the purging process.During a leak test, the housing is brought to a slight overpressure after purging and the pressure drop is monitored over a set period. Even small leaks — which are invisible to the naked eye in practice — can be detected this way. This is particularly relevant for systems operating across large temperature differentials or significant pressure variations, such as aviation and defence systems, where thermal expansion places extra stress on seals.
The Traqc-740: single-point purging with integrated verification
The Traqc-740 is built around the single-point principle, combining automatic purge cycles, real-time dew point measurement, and automated leak testing in one robust field system. Because the system runs multiple pressure-cycling steps and only stops once the dew point has reached the preset target, moisture is demonstrably removed from hygroscopic components.All measurement data is automatically logged and exportable, making every purge session fully traceable for quality assurance purposes. The IP67 field case with its included accessories makes the system immediately deployable on-site, without the need for additional equipment.
Click here to go to the product page of the Traqc-740.